6808 Fire Alarm Control Panel
Honeywell 6808 Addressable Fire Alarm Control Panel
The 198 point addressable fire alarm control panels include connected panel options, enhanced communications, wireless detection, and other advanced features. These panels also support Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit.
Categories: Fire Alarm, Honeywell

Description
Honeywell 6808 Addressable Fire Alarm Control Panel
The 198 point addressable fire alarm control panels include connected panel options, enhanced communications, wireless detection, and other advanced features. These panels also support Class B (Style 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuit.
Supply
24 - 35V with polarity

Activation Signal
Red LED

Alarm Consumption
35 mA

Temperature
-10ºC +50ºC
Additional information
Brand | |
---|---|
Product |
About Brand
IOT Hunt is introducing Honeywell
IOT Hunt is bring Honeywell to UAE, Saudi Arabia, UK, US, Oman, and Qatar. IOT Hunt are the leading IOT based integrator. We not only introduce IOT solutions but also provide quality products to its customers.

Specifications
CAPACITY | |
Intelligent Signaling Line Circuits | 1 |
Addressable device capacity | 198 (SK) or 127 (SD) |
Programmable software zones | 250 |
Output circuits | 4 which are expandable |
SBUS Devices | 20 (12 annuciators, 8 LED modules) |
ELECTRICAL | |
AC Power | 120 VAC, 60 Hz, 3.3 A |
Standby Current | 190 mA |
Alarm Current | 250 mA |
Communication Loop | Supervised and power-limited, Class A or Class B, 32VDC, 150mA |
Battery | Cabinet holds maximum of two 18 AH batteries |
Battery Charger Campatibility | 17-55 AH |
Temperature | 0 – 49°C (32– 120°F) |
PHYSICAL | |
Dimensions | 16.4” W x 26.4” H x 4.1” D (41.66cm W x 67.06cm H x 10.41cm D) |
Wieght | 45 lbs. (20.4 kg.) |
Color | Red |
CERTIFIED | |
Approvals | UL Listed: S2766 CSFM: 7165-0559:0502 FDNY: COA# 2023-TMCOAP-001168- RENL FM Approved Seismic: (CA) VMA-45894-05C |
Downloads
Related products
ML-051XX SMPS Power Supply
Maxlogic ML-051XX SMPS Power Supply
SPMS power supplies have a stable sensitivity, produced by using surface mount technology and compatible with all Maxlogic & Mavigard series products.◗ Compatible with EN 54-4
◗ In the case of electrical failure, power is supplied from battery, which are automatically recharged.
◗ Automatic battery charge circuit
◗ Battery charge voltage according to ambient temp.
◗ Earth fault, battery fault (charge fault, low voltage fault, no battery connection fault), power and fuse faults are monitored on the power supply unit
◗ Dry contact relay output for faults
◗ In case of electrical failure, supply from battery and protected from short circuit and over current
◗ Battery temperature measurement and automatically arrangement for battery charge voltage
ML-125XX Fire Alarm Panel
Maxlogic ML-125XX Fire Alarm Panel
Maxlogic series intelligent addressable fire alarm control panels are compatible with Mavigard series devices and designed for EN54-2, EN54-4 standards. Maxlogic series fire alarm control panels, offering high performance by the VIP communication protocol, provide 2032 address capacity with its expandable modular structure up to 16 loops. Maxlogic series intelligent analogue addressable fire alarm control panels use advanced microprocessor technology for high level security. LCD with 240x64 adjustable blue backlight indicates fire alarm, fault and other information detail. Panel menu, serigraphy and Loop Manager software have 3 language options as Turkish, English and Russian. Addressable detectors, buttons, loop-powered addressable sounders, interface modules (monitor and control modules) and analogue addressable gas detectors can be programmed, in order to operate in cause-effect scenarios and the fire automation can be built in this manner. Interaction to building management systems with Modbus and Bacnet protocols.Manual Call Point Pucar
Cofem Manual Call Point Pucar
Manual call point for the conventional fire detection system. It has an indicator of action (red led) that illuminates in case of be manually operated (alarm). Features: • Resettable call point by pushing yellow button on the front side. • Transparent protector cover to avoid accidental false alarms. • Immediate visual recognition of alarm status by the permanent activation of the LED, and the trigger of • The yellow tab on the lower side of the activation face. • According to EN 54-11 and CE mark according the European Regulation of Construction Products (UE) Nº305/2011.ML-0150 Recessed Mounting Base
Maxlogic ML-0150 Recessed Mounting Base
Recessed mounting base is used for mounting conventional and addressable detectors on false ceilings of various types (like metal, plaster etc.). The base allows creating more aesthetic architectural applications. Bases are produced from ABS and have the same color as detectors. Bases are mounted into ceiling material with minimum two clamps and stainless steel screws. They have an ergonomic design and easy in implementing. In usual ceilings where placed addressable devices, they can be installed directly under the mounting bases of the detectors, and in false ceilings – under the false ceiling unit. Address numerators are designed to provide great convenience in ⯑inding the right device, in case of fault, malfunction, contamination, etc. Compatible with all mounting bases of MaxLogic / MaviGard detectors and ceiling additions.ML-110X Sounder and Beacon
Maxlogic ML-110X Sounder & Beacon
Maxlogic Intelligent addressable loop-powered base sounder is designed for indoor use, in case of ?ire, user is warned by audible and visible warnings. Sounders are microprocessor controlled and outputs can be programmed to work within cause-effect scenarios. Mounting base c/w buzzer, in case of detector alarm, the internal buzzer of mounting base is activated.◗ Compatible with EN 54-3
◗ Specially designed for indoor use
◗ Loop-powered
◗ 85 dB sound output, 8 tones and volume control
◗ It can be used as a stand alone sounder/sounder beacon
◗ Its primary application is to be installed under intelligent analogue addressable smoke and heat detectors to provide both detection and alarm at the same point, reducing wiring and installation costs